SUB SEA TRANSMITTER
The CCI sub sea transmitter is designed specifically for the rigors of
sub sea well head service. Each of the main elements are crafted to
perform under the extreme conditions encountered in deep offshore
production.
FLANGE MOUNTING
The connecting flange housing is an API design fabricated from a wide
variety of corrosion resistant materials. It is a very robust
design and incorporates a 6BX type ring gasket.
SENSOR HOUSING
The sensor housing is designed for secondary containment. Should
the primary seals fail, a secondary housing within the transmitter is
capable of retaining up to 25,000 PSI, thereby preventing any release to
the environment. The cable housing is also rated to 5,000 PSI for
depths of 3000 meters.
SENSOR ELEMENTS
The temperature element is a 100 ohm Platinum RTD. It is a thin
film design and specially constructed to handle intense vibration and
shock. The pressure element is a sputtered thin film design which
excels at accuracy, temperature correction, and vibration.
TRANSMITTER ELECTRONICS
The pressure sensor and the temperature sensor have separate circuits
and circuit boards. Each sensor has a 4-20 mA output. The
circuit boards provide complete calibration and temperature
compensation. The boards are potted in place to withstand
vibration and shock.
CALIBRATION
Each transmitter comes with a detailed calibration sheet which shows
exact milliamp reading for a specific pressure or temperature. The
calibration sheet can be used to program controllers for even greater
accuracy.